Zawory nabojowe

Pilot Operated Sequence Valves of RS Series

RS pilot operated sequence valves are designed to connect secondary hydraulic system, or part of it, at a given pressure in the main system. These valves are insensitive to the pressure at the sequence port.

Maximum pressure 350 bar, maximum flow 60 through 480 lpm.

 

Zawory dołączające RS

Order Codes

 

RS2C-T11A-LAN

ab  -  c  -  def

a.  Valve name: RS;

b.  Valve size: 2C, 3C, 6C, 8C;

c.  Cavity type: T11A, T2A, T17A, T19A;

d.  Control manner : L: standard screw adjustment,  K: hand knob with lock knob;

e.  Adjustable range: A: 7~210 bar, B: 3,5~105 bar, N: 4~55 bar, W: 10~315 bar;

f.   Material of seals: N: buna-N, V: viton.

 

Symbol

Symbol zaworu dołączającego RS
 

Technical data

Pilot operated sequence valves
RS2C RS3C RS6C RS8C
Cavity type   T11A T2A T17A T19A
Maximum flow lpm 60 120 240 480
Maximum pressure bar 350 350 350 350
Tightening torque Nm 40/50 60/70 200/215 465/500
Temperature range °C -35~100 -35~100 -35~100 -35~100
Weight kg 0,17 0,30 0,64 1,43

.

 

Performance Graphs

Pressure drop full sequence


Charakterystyka zaworu dołączającego RS

 

Dimensions

Wymiary zaworu dołączającego RS


Dimension table
RS2C RS3C RS6C RS8C
a mm 34,9 34,9 46,0 63,5
b mm 22,2 28,6 31,8 41,3

L

c

K

mm

 

mm

64

 

70

72

 

78

84

 

90

100

 

107

.

Valve Cavities and Standard Valve Blocks

Full catalogue of cavities tooling of cartridge valves are ready for download:  download the catalogue

Links to our shop, and cartridge valve catalogue are available there:

Place an on-line orderDownload the catalogue

 